Table 4 machine diagnostic mode parameters – Baumfolder BAUM 26_30: Folder 1st Station Contfeed User Manual

Page 23

Advertising
background image

PAGE 23 TP10476-1

P23: Pause
This function is used to activate/deactivate a Pause counter. Select this parameter to display the period of time
for which the pause function was last engaged. It is not possible to feed in sheets when the Pause function is
activated.

P24: Network
Network is only displayed when "Network" is selected and enabled in the Service menu. Not available in
Software Version 100.300.

P25:Easy Mode
This function can only be used on machine types P-b20, C-b20, C-2020 and P-2020.

P26:Hardware and Firmware Version
Select this parameter to display the software installed in Service mode. The logic board type appears in the left
of the display. DCT displays a DCT 500 logic board.

P27:Machine Type
Select this parameter to view the Machine type specified in Service mode.

P28:Serial Port
Parameter setting in Service mode is displayed: dSp, nEt, Off

P30

Status Input Port 1
P30.1

P30.2

P30.3

P30.4

P30.5

P30.6

P30.7

P30.8

Pile Motor

Function

Pile Down

Pile Stop

Pile Up

Compress.

Compress.

Drive Start

Energized

Control K1

Button

Button

Button

Stop Button

Start Button

Relay K3

P31

Status Input Port 2
P31.1

P31.2

P31.3

P31.4

P31.5

P31.6

P31.7

P31.8

Pile Sensor

Double

Pile Down

Sheet Start

Sheet Stop

Thermal

Wrong Sheet

Emerg.Stop

Sheet Fault

Limit

Button

Button

Fault

Fault

Drive Stop

Button

P32

Status Input Port 3
P32.1

P32.2

P32.3

P32.4

P32.5

P32.6

P32.7

P32.8

Ergonomic

Jam on

Knife in

Jam on

Jam on

Suction

Delivery

Count sensor

Pile Load

Knife 3

Manual Mode Knife 2

Knife 1

Controller

Count Input

Suction

Eye

fail

Wheel

P33

Status Input Port 4
P33.1 N

P33.2

P33.3

P33.4

P33.5

P33.6

P33.7

P33.8

Board select

Board select

Not used

Not used

Not used

Not used

Not used

Not used

P34

Status Input Port 5
A34.1

A34.2

A34.3

A34.4

A34.5

A34.6

A34.7

A34.8

External

Setup

LT folding

External

K2 Checkback Emerg. stop

Emerg. stop

Machine

Mis-feed sht. Station 2

station

device

signal

station

guard open

Emerg. stop

delivery

protection

activated

P35

Status Output Port 1
P35.1

P35.2

P35.3

P35.4

P35.5

P35.6

P35.7

P35.8

Not used

Controller

Relief

Not used

Pile down

Pile up

Drive Stop

Pump

drive

valve/Tremat

active

is active

function

start (K4)

release

ON (K6)

Relay (K5)

Table 4 Machine diagnostic mode parameters