6.2 Run Time Fault Messages

Run time fault messages are only displayed when the unit is in Run mode. Fault errors can still occur, but the corresponding
fault message will not be displayed until the unit is switched to Run mode. Run time fault messages are PLC System Errors or
errors in the whole electric system. It is necessary to call an technician or service.

English

German

Codes

TYPE

DESCRIPTION

DCT

DCT

DCT

Information

This is the Software-Version(X.X.X)

X.X.X

X.X.X

X.X.X

Note:do not push any buttons until this message has been

cleared from the display

K5 Relay

K5 Relay

Error 7

PLC System

The drive stop relay, K5, is not responding to the controller.

Error

Action: Call service.

Button

Taste

Error 8

Electric

A push button is in the wrong state during the version

System Error

message display.
Action: Check Buttons & Cycle Power. If error persists call
service

Watchdog

Watchdog

Error 9

PLC System

The Watchdog Timer has elapsed without being serviced.

Error

Action: Cycle Power. If error persists call service

No Tach

Impuls

Error10

Electric

The Machine Tachometer is reading a velocity outside of the

System Error

range 10 – 230 meters per minute, while the main drive
should be running.
Action: Check the electric. If error persists call service.

Overload

Uberlast

Error11

Electric

A Thermal Overload has been tripped.

System Error

Action: Check the electric. If error persists call service

Pile Err

Spg. Uber

Error12

Electric

The Pile Safety Relay is stuck on or there is no power supply to

System Error

the pile circuits.
Action: Check the condition of Relay 1 K1, Fuses F1 and F2,
and X18, then cycle Power. If error persists call service

Overrun

Uberlauf

Error13

Electric

The Pile Table has moved past its safety stops.

System Error

Action: Check the limit switches, pile table, and wiring. If error
persists call service

2nd Stat

2Station

Error14

Electric

The Emergency Stop, Wrong Sheet, and Thermal Overload

System Error

sense circuits are all indicating failure. Likely cause is Second
Station connector problems.
Action: Check the Second Station Connector, connector X22,
and each individual circuit. If error persists call service

Suction

Saugtakt

Error15

Electric

Short circuit on Suction controller.

System Error

Action: Check the electric. If error persists call service

CLR Stop

CLR Stop

Error16

Electric

Emergency Stop activated during power-up sequence

System Error

ERROR 17

ERROR 17

Error17

Electric

Incorrect check-back signal received from K2 protective relay.

System Error

Power-up sequence (Check-back contact)

ERROR 18

ERROR 18

Error18

Electric

Incorrect check-back signal received from K2 protective relay.

System Error

Shutdown sequence (Check-back contact)

Table 19. Run Time Fault Messages