2.6 Production Mode

Enter Run Mode and Select Large Display Content

These keys do not operate as mode select keys in counter
setup. In all other modes, the keys both select the large
display (1) contents and place the counter into run mode.
Pushing one of the buttons will light the button’s associ-
ated LED and cause the parameter to be displayed. If both
the input and output count keys are pressed simulta-
neously, then both LEDs go on and the waste count is
displayed.

Table 13. Determining the Large Display Contents

When the folder is started with the RUN/MAINT jumper
in the RUN position, the system is enabled to fold paper.
The counter will start up in run mode, the normal operat-
ing mode of the counter. In this mode, various job param-
eters can be displayed on the large display (1), and the small
display (2) shows the gap length. The suction length
display (3) is active in this mode and shows the suction
length as a percentage of sheet length.

Gap Length Adjustment

The gap length adjustment keys allow the user to change
the current gap length. The range of adjustment is 0.2
inches to 98.0 inches (0.5cm to 250mm).

h

h

+

+

Suction Length Adjustment

The suction length adjustment keys allow the user to change
the amount of suction applied to the current sheet length. The
display shows the percentage in 5% steps. All of the bars must
be totaled to get the value. The range of adjustment is 5% to
50% of the current sheet length.

Reset Function

Pressing and holding this key will result in a reset function
being activated after a 5 second countdown. The function is
based on the current large display selection, see table 11. The
large display (1) will show countdown to reset in this manner.
When the button is pressed the message ‘CLr In 5’ will show
on the large display (1). At one second intervals the display
will progress through ‘CLr In 4’, ‘CLr In 3’, ‘CLr In 2’, ‘CLr
In 1’, and finally will show ‘CLEArEd’ when the reset action
is complete.

Table 14. Reset mode Selection

Exit Run Mode

Pressing any of these keys will cause the counter to change to a
new mode.

0

h

h

h

h

h

Output Count

Batch Count Down
Number of Batches

Current Rate

Input Count

Waste Count

Large Display Contents

Reset while showing Output Count will reset all job
variables.
Reset while showing batch data will reset Number
of Batches and reload the Batch Down Count.