Q60V Series Adjustable-Field Sensors –

Visible Red Emitter

page

4

Banner Engineering Corp.

Minneapolis, MN U.S.A.

www.bannerengineering.com • Tel: 763.544.3164

Color Sensitivity
The effects of object reflectivity on cutoff distance, though
small, may be important for some applications.

The excess gain curves on page 1 were generated using a white
test card of 90% reflectance. Objects with reflectivity of less
than 90% reflect less light back to the sensor, and thus require
proportionately more excess gain in order to be sensed with the
same reliability as more reflective objects. When sensing an
object of very low reflectivity, it may be especially important to
sense it at or near the distance of maximum excess gain.

It is expected that at any given cutoff setting, the actual cutoff
distance for lower reflectance targets will be slightly shorter
than for higher reflectance targets (see Figure 10). This
behavior is known as color sensitivity.

The percentage of deviation indicates a change in the cutoff
point for either 18% gray or 6% black targets, relative to the
cutoff point set for a 90% reflective white test card.

For example, the cutoff point decreases 4% for a 6%
reflectance black target when the cutoff point is adjusted for
1000 mm (40") using a 90% reflectance white test card. In
other words, the cutoff point for the black target is 960 mm
(38") for this setting.

Setting the Output Delay
The output of the Q60AFV sensor may be delayed between
0.008 and 16 seconds, in any of 72 increments. Delay is
indicated on the 5-segment light bar using single LED
segments or combinations of them, in varying stages of
intensity. Major increments, displayed by a single full-intensity
LED, are shown in Figure 13.

Figure 10. Q60V Cutoff point deviation

0

-1

-2

-3

-4

-5

200

300

400

500

600

700

800

900

1000

Cutoff Setting (90% White Card)

Percent Deviation

18% Gray Card
6% Black Card

Figure 11. Q60V minimum range vs. cutoff setting

150

140

130

120

110

100

90

80

70

60

50

200

400

600

800

1000

Cutoff Distance (mm) with 90% White Card

Minimum Range with a 6% Black Card (mm)

Figure 12. Q60V hysteresis

Figure 13. ON/OFF Delay options

2.0

1.5

1.0

0.5

0

200

400

600

800

1000

Cutoff Setting (mm) with 90% White Card

Hysteresis (% of Cutoff) with 6% Black Card

Step

#

Delay

Time

0

No

Delay

8

0.062

second

24

0.250

second

40

1.00

second

56

4.0

seconds

72

16

seconds

DO

SIG

LO

DO

SIG

LO

DO

SIG

LO

DO

SIG

LO

DO

SIG

LO

DO

SIG

LO

LED

Status