Q60v series adjustable-field sensors, Visible red emitter, Q60v specifications – Banner Q60 Background Suppression Series User Manual

Page 7

Advertising
background image

page

7

Q60V Series Adjustable-Field Sensors –

Visible Red Emitter

Banner Engineering Corp.

Minneapolis, MN U.S.A.

www.bannerengineering.com • Tel: 763.544.3164

Q60V Specifications

Sensing Hysteresis

Output Rating

Q60BB6AFV models
150 mA maximum each output @ 25° C
Off-state leakage current: < 5µA @ 30V dc
Output saturation NPN: < 200 mV @ 10 mA and < 1V @150mA
Output saturation PNP: < 1V at 10 mA; < 1.5V at 150 mA

Q60VR3AFV Universal models
Min. voltage and current:
5V dc, 10 mA
Mechanical life of relay: 50,000,000 operations
Electrical life of relay at full resistive load: 100,000 operations
Max. switching power (resistive load):

Cabled models: 1250VA, 150 W

QD models: 750VA, 90W

Max. switching voltage (resistive load): Cabled models: 250V ac, 125V dc QD models: 250V ac, 125V dc
Max. switching current (resistive load):

Cabled models: 5 A @ 250V ac, 5 A @ 30V dc derated to 200 mA @ 125V dc
QD models: 3 A @ 250V ac, 3 A @ 30V dc derated to 200 mA @ 125V dc

Output Protection Circuitry

Q60BB6AFV models: Protected against continuous overload or short circuit of outputs
All models: Protected against false pulse on power-up

Output Response Time

Repeatability

500 microseconds

See Figure 12.

Construction

Housing: ABS polycarbonate blend Lens: Acrylic Cover: Clear ABS

Environmental Rating

IEC IP67; NEMA 6

Connections

2 m (6.5') or 9 m (30') attached cable, 5-pin Euro-style fitting, or 5-pin Mini-style 150 mm (6") QD pigtail,
depending on model. QD cables are ordered separately; see page 8.

Operating Conditions

Temperature: -20° to +55°C (-7° to +131°F)
Maximum Relative Humidity: 90% at 50°C (non-condensing)

Indicators

NOTE: Outputs are active

during on/off timing
selection mode.

ON Delay

Steady Green: Run mode, ON delay is active
Flashing Green: ON Delay Selection mode is active

OFF Delay

Steady Green: Run mode, OFF delay is active
Flashing Green: OFF Delay Selection mode is active

5-Segment Light Bar*:

Indicates relative delay time during ON or OFF Delay Selection modes

Output

Steady Amber: Outputs are conducting
Steady Green: During ON/OFF Delay Selection modes

Dark Operate

Steady Green: Dark Operate is selected

Lockout

Steady Green: Buttons are locked out

Light Operate

Steady Green: Light Operate is selected

Signal

Steady Green: Sensor is receiving signal
Flashing Green: Marginal signal (1.0 to 2.25 excess gain)

*Output, Dark Operate, Lockout, Light Operate and Signal indicators function as 5-Segment Light Bar during

ON or OFF Delay Selection modes

Adjustments

2 momentary push buttons: ON Delay (+) and OFF Delay (–) (DC models also have remote program wire)

ON Delay select: 8 ms to 16 seconds

OFF Delay select: 8 ms to 16 seconds
LO/DO select
Push button lockout
for security

Slotted, geared, 2-turn, cutoff range adjustment screw (mechanical stops on both ends of travel)

Q60BB6AFV models: 2 milliseconds ON and OFF
NOTE: 150 millisecond delay on power-up; outputs do not conduct during this time.
Q60VR3AFV Universal models: 15 milliseconds ON and OFF
NOTE: 150 millisecond delay on power-up; relay is de-energized during this time.

Certifications