Programming the Sensing Window Limits

The Q45UR controller features a single push button for
programming the sensing window limits (Figure 1). The
window limits may be set in one of two ways:
programming two independent window limits, or defining a
sensing distance set point, which will be centered
automatically within a 5-mm window (specific steps are
described on page 5).

Independent Window Limits: The target is placed at the
desired position to set the first limit, then the second limit
is set using the same procedure. In order to set two
independent limits, the window must at least 5 mm.

Sensing Distance Set Point: The sensor is taught the same
set point for both window limits. The set point is
automatically centered within a 5-mm (0.2") window.

See page 5 for detailed programming instructions.

Status Indicators

Status indicator LEDs are visible through the transparent,
o-ring sealed Lexan

®

top cover. Indicator function in the

RUN mode is, as follows:

The green LED is ON steadily whenever power is
applied to the sensor, and flashes to indicate a
current output fault.

The red LED lights when an echo is received, and
flashes at a rate that is proportional to echo strength.

The yellow LED lights whenever the target is within
the operating window limits.

The 5-segment moving dot LED indicator displays the relative
position of the target within the programmed sensing window.
The #1 LED flashes when the target is closer than the near
limit. The #5 LED flashes when the target is beyond the far limit.

1

ON

2

3

4

See Table Below for

Programming Information

Limits

N

1 2 3 4 5

Green Power
Indicator

Red Signal
Indicator

Yellow Output
Indicator

Response
Speed Selector
(10 to 320 ms)

Sensing

Window Limits

Programming

Push Button

5-Segment Target

Position Indicator

(N = Near)

Slots for Inner
Cover Removal

Figure 1. Analog Q45UR controller features

Figure 2. Analog Q45UR controller programming DIP switches

(factory default settings)