U-gage, Q45u series hookup diagrams q45u series dimensions, Pin mini-style pin-out (cable connector shown) – Banner U-GAGE Q45U Series—Analog User Manual

Page 7: Pin euro-style pin-out (cable connector shown)

Advertising
background image

U-GAGE

Q45U Ultrasonic Sensors with Bipolar Discrete Outputs

P/N 44177 Rev. D

7

Banner Engineering Corp.

Minneapolis, MN U.S.A.

www.bannerengineering.com • Tel: 763.544.3164

Q45U Sensor with 5-Pin

Mini-Style QD

(“Q” model Suffix)

Q45U Sensor with Attached Cable

bn

wh

bu

+

bk

ye or gy

Load

12-24V dc

Enable
(+5-24V dc)

Load

shield*

bn

wh

bu

+

bk

ye

Load

Load

12-24V dc

Enable
(+5-24V dc)

shield*

Q45U Sensor with 5-Pin

Euro-Style QD

(“Q6” model Suffix)

bn

wh

bu

+

bk

gy

Load

Load

12-24V dc

Enable
(+5-24V dc)

shield*

5-Pin Mini-Style Pin-out

(Cable Connector Shown)

Black Wire

Blue Wire

Brown Wire

Yellow Wire

White Wire

5-Pin Euro-Style Pin-out

(Cable Connector Shown)

White Wire

Blue Wire

Black Wire

Brown Wire

Gray Wire

14 mm (0.6")

Q45U Sensor with Attached Cable

Q45U Sensor with 5-Pin Mini-Style QD

(“Q” model Suffix)

15 mm (0.6")

Q45U Sensor with 5-Pin Euro-Style QD

(“Q6” model Suffix)

Q45U Series Hookup Diagrams

Q45U Series Dimensions

60.5 mm

(2.38")

44.5 mm

(1.75")

69.0 mm

(2.72")

87.6 mm

(3.45")

30.0 mm

(1.18")

7.1 mm

(0.28")

4.5 mm (#10) Screw
Clearance (2)

50.8 mm

(2.00")

6.4 mm (0.25")

Transducer
Centerline

Internal Thread

(1/2–14NPSM)

External Thread

M30 X 1.5

ø 6.1 (0.24")
2m (6.5') Cable

Hex Nut Supplied

Transparent Cover (Gasketed)
View: Sensing Status

Output Load Status

Power

Open to Access:

Push Button for

Programming of Sensing

Window Limits

*It is recommended that the shield wire be connected

to earth ground or dc common.

Advertising