Qs18expert sensor, Setup, Sensing limit configuration options include – Banner WORLD-BEAM QS18 Series User Manual

Page 3: Change that setting or the off-delay setting, see, Qs18expert sensor setup, Sensor setup

Advertising
background image

Remote Configuration

Use the remote function to configure the sensor remotely or to disable the push button for security. Connect the white wire

of the sensor to ground (0V dc), through a remote programming switch. Pulse the remote line according to the diagrams in

the configuration procedures. The length of the individual programming pulses is equal to the value T: 0.04 seconds ≤ T ≤

0.8 seconds

Push Button Enable/Disable

The remote input may be used to disable the sensor push button to prevent unauthorized adjustment. Connect the white

wire of the sensor as described above to perform the procedure below to either enable or disable the feature.

Push Button Enable/Disable

Push Button ( 0.04

seconds ≤ "Click" ≤ 0.8

seconds)

Remote Line ( 0.04 seconds ≤ T

≤ 0.8 seconds)

Result

Not available

From Run mode, four-pulse the

remote line.

T

T

T

T

T

T

T

Sensor toggles between enable/disable settings and

returns to RUN mode.

Power LED: Flashes 3x, then ON Green

Output LED: OFF,

2

then ON or OFF, depending on

output state

Returning to RUN Mode without Saving Settings

Exit Static TEACH and Set modes after the automatic 60-second time-out or by manually exiting the process. To manual

exit, press and hold the push button (or hold the remote line low) for 2 seconds. The sensor returns to Run mode without

saving any new settings.

Sensor Setup

Access setup functions directly from Run mode using the following procedures.

30 ms OFF-Delay (Pulse Stretcher) Enable/Disable

Push Button (0.04 seconds ≤
“Click” ≤ 0.8 seconds)

Remote Line (0.04 seconds ≤ T ≤
0.8 seconds)

Results

From Run mode, six-click the
push button.

From Run mode, six-pulse remote line.

T

T

T

T

T

T

T

T

T

T

T

Sensor toggles between enable/disable settings and
returns to Run mode.

Power LED: Flashes 3x, then ON Green
Output LED: Enabled – ON, 3
Disabled – OFF, 3
Then ON or OFF, depending on output state

Light-Operate/Dark-Operate Select

Push Button (0.04 seconds ≤
“Click” ≤ 0.8 seconds)

Remote Line (0.04 seconds ≤ T ≤
0.8 seconds)

Results

From Run mode, seven-click the
push button.

From Run mode, seven-pulse remote
line.

T

T

T

T

T

T

T

T

T

T

T

T

T

Sensor toggles between Light-/Dark-Operate settings
and returns to Run mode.

Power LED: Flashes 3x, then ON Green
Output LED: Light Operate – ON, 3
Dark Operate – OFF, 3
Then ON or OFF, depending on output state

2 Initial output LED condition is simultaneous with Power LED 3-flash

3 Initial Output LED condition is simultaneous with Power LED 3-flash.