Dark set – Banner WORLD-BEAM QS18 Series User Manual

Page 7

Advertising
background image

Dark Set

Darkest

(no signal)

Most Light

(saturated

signal)

Output OFF

Output ON

Single

Presented

Condition

Sensor positions

threshold ≈12.5% above

the presented condition

Figure 6. Dark Set (Light Operate shown)

Dark Set sets a threshold approximately 12.5%

above the presented sensing condition.

Any condition lighter than the threshold causes the

output to change state.

In Light-Operate mode, the presented condition is

the Output OFF condition. In Dark-Operate mode,

the presented condition is the Output ON condition.

To change the Light-/Dark-Operate setting, see

Sensor Setup

on page 3.

Dark Set is recommended for applications where

only one condition is known, for example a stable

dark background with varying lighter targets, or

when maximum excess gain is required.

1. Access the Dark Set mode.

Method

Action

Result

Push Button

Press and hold the push button 2 to 4

seconds.

The sensor waits for the sensing

condition.
Power LED Indicator: OFF

Output LED Indicator: Slow flash (1

Hz)

Remote Line Single-pulse the remote line.

T

The sensor waits for the sensing

condition.
Power LED Indicator: OFF

Output LED Indicator: Double-flash

2. Set the sensing condition.

Method

Action

Result

Push Button

Present the sensing condition, then five-click

the push button.

TEACH Accepted
Power LED Indicator:
Flashes 3

times, then solid green

Output LED Indicator: OFF6, then

ON or OFF, depending on the output

state

The sensor returns to Run mode with

the new settings.

TEACH Not Accepted
Power LED Indicator:
OFF

Output LED Indicator: Slow flash (1

Hz)

The sensor returns to the wait state,

ready for the sensing condition.

Remote Line

Present the sensing condition, then five-pulse the remote line.

T

T

T

T

T

T

T

T

T

6 The initial output LED indicator condition is simultaneous with the power LED indicator 3-flash.

WORLD-BEAM

®

QS18E Series

P/N 136564 Rev. C

www.bannerengineering.com - tel: 763-544-3164

7

Advertising