M-GAGE Gateway DIP Switches

The special M-GAGE Gateway, models DX80G*M6*6P6ZP, can configure up to two M-GAGE Nodes. To use the special M-GAGE Gateway’s
DIP switches to configure the M-GAGE Node, refer to the M-GAGE Gateway data sheet, Banner p/n 139075.

Configuration Using Register 13

A host system can configure the M-GAGE Node by setting I/O 13 on the M-GAGE Node. Writing a defined value to the Modbus register sets
the M-GAGE operation immediately. The following parameters can be configured by writing to the M-GAGE Node Modbus register 13. The host
system must resend the configuration settings if power is cycled to the wireless system.

Modbus Register 13

Low Pass Filter

Sample High

Counter

Report

Rate

Sample Rate

Baseline

Filter

Threshold and

Hysteresis

Device Settings

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

No Change

0

0

0

No Low Pass Filter

0

0

1

Low Pass Filter T0

0

1

0

Low Pass Filter T1

0

1

1

Low Pass Filter T2

1

0

0

Low Pass Filter T3

1

0

1

Low Pass Filter T4

1

1

0

Low Pass Filter T6

1

1

1

No Change

0

0

0

1

0

0

1

2

0

1

0

3

0

1

1

4

1

0

0

8

1

0

1

16

1

1

0

32

1

1

1

No Change

0

0

Change of State

0

1

16 sec

1

0

Sample Rate

1

1

No Change

0

0

0

62.5 ms

0

0

1

125 ms

0

1

0

250 ms

0

1

1

500 ms

1

0

0

1 sec

1

0

1

31 ms

1

1

0

20 ms

1

1

1

No Change

0

0