Sensor hookup diagrams for ma3-4 micro-amp modules, Extension cable, Continued) – Banner MICRO-AMP Series User Manual

Page 10: Cable protection

Advertising
background image

Modulated remote sensors require specially de-
signed cable for efficient sensor performance.
Extension cable is available in 100 foot (30m)
lengths.

Extension Cable

This is mild-steel flexible tubing used
with the compression fittings, at right,
to achieve maximum protection to
sensor cables.
I.D. = 5/16"; O.D. = 7/16".

Accessories for High Performance Modulated Remote Sensors

PVC-6 6 feet (1,8m)
PVC-30 30 feet (9m)

Hookup of LR300 and PT300

Hookup of SP300D, SP300L, LP400WB, SP1000V

Hookup of SP320D

Sensor Hookup Diagrams for MA3-4 MICRO-AMP Modules

(continued)

Remote sensor cables may be run up to 30 feet (9m) away from the MA3-
4 amplifier. All sensor models are available from the factory with 30 feet
of cable, installed as an option.

When splicing additional cable to the standard 6-1/2 foot length, it is
important to use a separate shielded cable for emitter and receiver wires.
Combining emitter and receiver wires together in the same cable (even if
the cable is shielded) will result in direct coupling of the emitter signal to
the receiver leads.

This is called "cable crosstalk" and will not allow full amplifier sensitivity
setting without an amplifier "lock on" situation, which appears as a
continuous LIGHT condition. Banner offers 100 foot (30m) lengths of
sensor extension cable (see below) which, if used for cable splicing, will
minimize the chances for cable crosstalk.

IMPORTANT : Cable Splicing Information

Heavy duty PVC tubing used to pro-
tect sensor cable in applications in-
volving moisture and/or corrosive
materials. I.D. = 1/4"; O.D. = 3/8".

Extension Cable
Model

ESC-100

RSC-100

SSC-100

EC300E-100

EC300R-100

EC320-100

Used on Sensor Models

# of
Wires

Wire Colors

White, Green, Shield

Red, Black, Shield

White, Green, Red, Black,
Shield

White, Shield

Red, Shield

White, Shield, Red, Shield

PT200, PT250, PT400,
SP300RL

LR200, LR250, LR400,
SP300EL

SP300D, SP300L, LP400WB,
SP1000V

LR300

PT300

SP320D

3

3

5

2

2

4

Cable Protection

AC-6 6 feet (1,8m)
AC-30 30 feet (9m)

10

LR400, PT400, LP400WB

Compression Fittings used to Attach
Protective Tubing to Remote Sensors

CF3-8 3/8"-32 thread
CF7-16 7/16"-20 thread

Used to Attach Tubing
to these Models

Compression Fitting
Model

SP300EL, SP300RL, SP300D,
SP300L, LR200, PT200

CF3-8

CF7-16