Opposed mode, Beam pattern, Excess gain models/dimensions – Banner MICRO-AMP Series User Manual

Page 6

Advertising
background image

Beam Pattern

OPPOSED Mode

LR/PT200, 250, 300, and 400 opposed mode remote sensors are
identical electronically and optically, and differ only in their housings.
All are totally epoxy-encapsulated and use hermetically sealed glass
lenses to eliminate condensation inside the optical chamber. These
sensors may be washed down without damage. Operating temperature
is determined by the type of cable used (see specifications above). All
models have a wide beam angle for forgiving line-of-sight alignment.
At the same time, the effective beam of each pair is only 1/8 inch,
allowing small-profile resolution and reliable response to fast-moving
objects. LR models are emitters, and PT models are receivers.

LR200 & PT200: this is a right-angle design which mounts through
a 7/16 inch (12mm) diameter hole, using the steel jam nut which is
included. This pair is used most commonly on small conveyors when
it is desireable to run the cable directly down to a wireway.

LR250 & PT250: these sensors feature a 1/4 inch (6,4mm) diameter
smooth barrel design, and are usually held in place in a clearance hole
with a small set-screw. Optional mounting blocks (shown below) are
available. Model SMB250 holds the sensor in place with two set-
screws. The block is then mounted to a bracket (such as model
SMB300), or directly to a machine frame with two #6 screws. Block
model SMB250C holds an LR & PT250 together to converge at
approximately 1/2 inch ahead of the block.

L4 lens

L16 lens

The LR/PT400 pair is often used at close range with optional AP400 aperture
assemblies to create a very small and well-defined effective beam for resolving
small profiles, increasing sensing repeatability, or easing response time require-
ments.

Aperture model

AP400-010
AP400-015
AP400-040
AP400-030R

LR200 & PT200

LR250 & PT250

LR300 & PT300

LR400 & PT400

Temp. range: -40 to +100

°

C

Housing material: black Delrin

®

Temp. range: -40 to +100

°

C

Housing material: black Delrin

®

Temp. range: -40 to +80

°

C

Housing material: black VALOX

®

Temp. range: -40 to +100

°

C

Housing material: anod. aluminum

AP400 apertures

Excess Gain

Models/Dimensions

ALL MODELS
Range:
8 feet (2,4m)
Beam: infrared, 880nm
Effective Beam:
0.14 inch (3,6mm) dia.

PT models are receivers
LR models are emitters

SMB250

SMB250C

LR & PT300: this is a miniature right-angle design which is mounted
in place using two #4 screws. This pair uses a very flexible, low-
profile 2-wire cable. Despite their small size, the optical performance
of the LR/PT300 is equal to the other remote sensor pairs.

LR400 & PT400: the 3/8 inch (9,5mm) diameter threaded barrel
design makes the LR/PT400 the most versatile and most popular
remote opposed sensor pair. They are easily mounted through clear-
ance holes using the jam nuts which are supplied. They may be used
with optional L4 or L16 lenses for extended range and/or higher excess
gain. The addition of an L4 lens on both the LR and PT400 will
increase their range from 8 feet to 40 feet and increase the excess gain
at any distance by a factor of 25X. A pair of L16 lenses will increase
available excess gain by a factor of 250X.

Aperture size

.010" dia.
.015" dia.
.040" dia.
.030" x .125"

10

1

DISTANCE

100

1000

.1 FT

1 FT

10 FT

100 FT

E
X
C
E
S
S

G
A
I
N

I

LR/PT200, 250,
300, & 400

2

0

0

I
N
C
H
E
S

OPPOSED DISTANCE--FEET

4

6

8

10

4

8

12

4

8

12

LR/PT200, 250,
300, 400

Sensors are epoxy-encapsulated and optics are hermetically sealed. Cables are 6 -1/2 feet (2m) long. 30-foot (9m) cables available by special order.

Sensors for use with MA3-4 and MA3-4P Modulated Amplifiers