Micro-amp, System – Banner MICRO-AMP Series User Manual

Page 19

Advertising
background image

SUPPLY VOLTAGE: model MPS-15 is for 105 to 130V ac (50/
60Hz); model MPS-15-230 is for 210 to 250V ac (50/60Hz).

OUTPUT CONFIGURATION: SPDT electromechanical relay.
Contact rating: 250V ac max., 30V dc max., 5 amps max. (resistive
load). Install MOV (metal oxide varistor) transient suppressor of
appropriate voltage across contacts used to switch inductive loads.
*Contact response: 20 milliseconds open and close.
Mechanical life: 10,000,000 operations.

*NOTE: dc loads may be easily connected directly to the output(s) of
the MICRO-AMP module used with the chassis in order to bypass the

Specifications

NOTE: for hookup of sensors or inputs to the module socket,
see the hookup diagram for the module used.

Hookup Diagram, MPS-15 & MPS-15-230

Dimension Drawing, MPS-15 & MPS-15-230

MPS-15 Series power supplies are designed specifically to supply power for the Banner
MICRO-AMP series amplifiers and logic modules. They are constructed on small
PC boards that are track-mountable for compatibility with other track-mounted MICRO-
AMP components. The MPS-15 includes a socket for a MICRO-AMP amplifier or logic
module. The combination of an MPS-15 series power supply and a MICRO-AMP
module makes a complete and compact sensing and/or control system.

A built-in 5-amp rated SPDT output relay is supplied for easy interfacing to an external
load or circuit. Its action is controlled by the outputs of a MICRO-AMP module which
is plugged into the on-board module socket. A switch on the PC board selects which
module output (normally open or normally closed) will activate the relay.

Two models are available. Model MPS-15 is for 120V ac operation. Model MPS-15-
230 is for 220/240V ac power. Up to three MICRO-AMP modules may be powered
by one MPS-15 power supply. A 4-inch (100mm) long mounting track is supplied
with each MPS-15. Optional 6-inch (150mm) track model TR100-6 neatly
accomodates the MPS-15 Series PC board plus the PC boards of two additional RS8
sockets to form a complete three-module MICRO-AMP sensing/logic system.

MICRO-AMP

®

System

MPS-15 and MPS-15-230 Power Supplies

19

relay and therefore take advantage of the 1 millisecond response time
of the module (see MICRO-AMP module specifications and hookup).

COMPATIBLE MODULES: models MA3, MA3A, MA3-4, MA4-
2, MA4G, MA4L, MA5. Do not plug modules with current-sourcing
PNP outputs (MA3P, MA3-4P, etc.) into the socket on the MPS-15.

POWER FOR EXTERNAL DEVICES: 40 milliamps is available
to power external 10 to 30V dc devices (e.g.- two additional MICRO-
AMP modules or two MINI-BEAM sensors, etc.).

OPERATING TEMPERATURE:
-40 to 70 degrees C (-40 to 158 degrees F).