Push button lockout – Banner U-GAGE QT50U DC Series—Analog User Manual

Page 6

Advertising
background image

Remote Line Method (0.04 s < T < 0.8 s)

Step

Action

Result

1

Position the target at the location where the midpoint of the
window should be.

Min and Max LEDs both flash red (0.5 second), then turn
amber

2

Triple-pulse the remote line

T

T

T

T

T

Setting the Maximum Analog Limit

Push Button Method

Step

Action

Result

1

Position the target at the location where the midpoint of the
window should be.

Its LED flashes red

2

“Click” either push button

3

“Click” the other push button

The Red Teach LEDs change to amber and the sensor returns
to RUN mode

Remote Line Method (0.04 s < T < 0.8 s)

Step

Action

Result

1

Position the target at the location where the midpoint of the
window should be.

Min and Max LEDs both flash red (0.5 second), then turn
amber

2

Triple-pulse the remote line

T

T

T

T

T

Push Button Lockout

Enables or disables the keypad to prevent unauthorized personnel from adjusting the programming settings.

Push Button

Remote Line

Procedure

Result

Procedure

0.04 sec. < T < 0.8 sec.

Result

Not available via push button

Not applicable

Four-pulse the remote line

T

T

T

T

T

T

T

Push buttons are either enabled or

disabled, depending on previous

condition.

U-GAGE QT50ULB Series Sensors with Analog Output

6

www.bannerengineering.com - tel: 763-544-3164

P/N 70137 Rev. B

Advertising
This manual is related to the following products: