Status indicators – Banner U-GAGE QT50U DC Series—Analog User Manual

Page 7

Advertising
background image

Status Indicators

Min

Max

Min

Power Signal

Power Signal

Power Signal

Power Signal

Max

Min

Max

Min

Max

Minimum

Operating

Range

Minimum

Analog

Setpoint

Maximum

Analog

Setpoint

Maximum

Operating

Range

Target Within

Limits

Target Outside

Min Limit

Target Outside

Sensing Range

Target Outside

Max Limit

Target

Target

Target

Target

Figure 5. Status Indicator Conditions for Each Target Position

Signal LED (Red) – indicates the strength and condition of the sensor’s incoming signal.

Signal LED Status

Indicates

ON Bright

Good signal

ON Dim

Marginal signal strength

OFF

No signal is received or the target is beyond the sensor’s range limitations

Output LEDs (Amber) – indicate the position of the target relative to the window limits.

Output/Teach LED

Indicates

ON Red (either)

In Teach mode; waiting for limits to be taught

Min Analog ON Amber

Max Analog ON Amber

Target is within analog window limits

Min Analog ON Amber

Max Analog Flashing Amber

Target is outside max. window limit

Min Analog Flashing Amber

Max Analog ON Amber

Target is outside Min window limit

Min Analog OFF

Max Analog OFF

No signal condition or Outside operating limits

Power ON/OFF LED (Green) – indicates the operating status of the sensor.

Power ON/OFF LED

Indicates

OFF

Power is OFF

Flashing at 2 Hz

Transmit disabled (see DIP switch settings)

ON Solid

Sensor is operating normally

U-GAGE QT50ULB Series Sensors with Analog Output

P/N 70137 Rev. B

www.bannerengineering.com - tel: 763-544-3164

7

Advertising
This manual is related to the following products: