05 input wiring specifications, Input wiring specifications -3 – Tweco CutMaster 12mm-20mm-25mm User Manual

Page 17

Advertising
background image

CUTMASTER 12mm, 20mm, 25mm

Manual 0-5117 2-3 INTRODUCTION

22.5"

0.57 m

43 lb / 19.5 kg

10.75"

273 mm

16.375"

416 mm

Art # A-07941

6"

150 mm

24"

610 mm

6"

150 mm

6"

150 mm

Art # A-07925_AB

Power Supply Dimensions & Weight Ventilation Clearance Requirements

2.05 Input Wiring Specifications

CutMaster 12mm Power Supply Input Cable Wiring Requirements

Input voltage

Freq

Power Input

Suggested Sizes

Volts

Hz

kVA

I max

I eff

Fuse (amps)

Flexible Cord

(AWG)

3 Phase

380

50/60

5.3

8

5

10

16

400

50/60

5.3

8

5

10

16

CutMaster 20mm Power Supply Input Cable Wiring Requirements

Input voltage

Freq

Power Input

Suggested Sizes

Volts

Hz

kVA

I max

I eff

Fuse (amps)

Flexible Cord

(AWG)

3 Phase

380

50/60

11

16

11

20

14

400

50/60

11

16

11

20

14

CutMaster 25mm Power Supply Input Cable Wiring Requirements

Input voltage

Freq

Power Input

Suggested Sizes

Volts

Hz

kVA

I max

I eff

Fuse (amps)

Flexible Cord

(AWG)

3 Phase

380

50/60

11.8

18

12

20

14

400

50/60

11.8

17

11

20

14

Line Voltages with Suggested Circuit Protection and Wire Sizes

Based on National Electric Code and Canadian Electric Code

NOTE

Refer to Local and National Codes or local authority having jurisdiction for proper wiring requirements.
Cable size is de-rated based on the Duty Cycle of the equipment.

Advertising