SERVICE 5-8 Manual 0-5117

Optional Two-Stage Filter Element

Replacement

The Two-Stage Air Filter has two Filter Elements.

When the Filter Elements become dirty the Power

Supply will continue to operate but cut quality may

become unacceptable. Refer to Section 6, Parts List,

for replacement filter element catalog number.

1. Shut OFF primary input power.

2. Shut OFF air supply and bleed down system.

WARNING

Always turn OFF the air supply and bleed the

system before disassembling the Filter Assembly

as injury could result.

3. Loosen the two bolts on the top of the Filter

Assembly enough to allow the Filter Elements

to move freely.

4. Note the location and orientation of the old

Filter Elements.

5. Slide out the old Filter Elements.

First & Second

Stage

Cartridges

(as marked)

Art # A-02942

Optional Two-Stage Filter Replacement

6. Slide the replacement Filter Elements into the

Filter Assembly, with the same orientation as

noted in Step 4 above.

7. Hand tighten the two bolts evenly, then torque

each bolt to 20 - 30 in-lbs (2.3 - 3.4 Nm). Im-

proper torque may damage the gasket.

8. Slowly apply air pressure to the assembly,

checking for leaks.

NOTE

A small amount of air leakage from the bottom

fitting is normal.

This completes the parts replacement procedures.