SERVICE 5-2 Manual 0-5117

5.02 Maintenance Schedule

NOTE

The actual frequency of maintenance may need

to be adjusted according to the operating envi-

ronment.

Daily Operational Checks or Every Six

Cutting Hours:

1. Check torch consumable parts, replace if dam-

aged or worn.

2. Check plasma and secondary supply and pres-

sure/flow.

3. Purge plasma gas line to remove any moisture

build-up.

Weekly or Every 30 Cutting Hours:

1. Check fan for proper operation and adequate

air flow.

2. Inspect torch for any cracks or exposed wires,

replace if necessary.

3. Inspect input power cable for damage or ex-

posed wires, replace if necessary.

Six Months or Every 720 Cutting Hours:

1. Check the in-line air filter(s), clean or replace as

required.

2. Check cables and hoses for leaks or cracks,

replace if necessary.

3. Check all contactor points for severe arcing or

pits, replace if necessary.

4. Vacuum dust and dirt out of the entire machine.

CAUTION

Do not blow air into the power supply during

cleaning. Blowing air into the unit can cause

metal particles to interfere with sensitive electri-

cal components and cause damage to the unit.

5.03 Common Faults

Problem -

Symptom

Common Cause

Insufficient

Penetration

1. Cutting speed too fast.

2. Torch tilted too much.

3. Metal too thick.

4. Worn torch parts

5. Cutting current too low.

6. Non - Genuine Thermal Dynamics

parts used

7. Incorrect gas pressure

Main Arc

Extinguishes

1. Cutting speed too slow.

2. Torch standoff too high from

workpiece.

3. Cutting current too high.

4. Work cable disconnected.

5. Worn torch parts.

6. Non - Genuine Thermal Dynamics

parts used

Excessive Dross

Formation

1. Cutting speed too slow.

2. Torch standoff too high from

workpiece.

3. Worn torch parts.

4. Improper cutting current.

5. Non - Genuine Thermal Dynamics

parts used

6. Incorrect gas pressure

Short Torch Parts

Life

1. Oil or moisture in air source.

2. Exceeding system capability

(material too thick).

3. Excessive pilot arc time

4. Gas pressure too low.

5. Improperly assembled torch.

6. Non - Genuine Thermal Dynamics

parts used

Difficult Starting 1. Worn torch parts.

2. Non - Genuine Thermal Dynamics

parts used.

3. Incorrect gas pressure.

Advertising