Tweco CutMaster 12mm-20mm-25mm User Manual

Page 26

Advertising
background image

CUTMASTER 12mm, 20mm, 25mm

INSTALLATION 3-4 Manual 0-5117

Using High Pressure Air Cylinders

When using high pressure air cylinders as the air

supply:

1. Refer to the manufacturer’s specifications

for installation and maintenance proce-

dures for high pressure regulators.

2. Examine the cylinder valves to be sure

they are clean and free of oil, grease

or any foreign material. Briefly open

each cylinder valve to blow out any dust

which may be present.

3. The cylinder must be equipped with

an adjustable high - pressure regulator

capable of outlet pressures up to 100 psi

(6.9 bar) maximum and flows of at least

300 scfh (141.5 lpm).

4. Connect supply hose to the cylinder.

NOTE

Pressure should be set at 100 psi (6.9 bar) at

the high pressure cylinder regulator.
Supply hose must be at least 1/4 inch (6 mm)

I.D.
For a secure seal, apply thread sealant to the

fitting threads, according to manufacturer's

instructions. Do Not use Teflon tape as a

thread sealer, as small particles of the tape

may break off and block the small air passages

in the torch.

Advertising