Section 3 system: installation, 01 unpacking, 02 lifting options – Tweco CutMaster 12mm-20mm-25mm User Manual

Page 23: 03 primary input power connections, Section 3 system: installation -1, 01 unpacking -1 3.02, Lifting options -1, Primary input power connections -1

Advertising
background image

CUTMASTER 12mm, 20mm, 25mm

Manual 0-5117 3-1 INSTALLATION

SECTION 3 SYSTEM:

INSTALLATION

3.01 Unpacking

1. Use the packing lists to identify and ac-

count for each item.

2. Inspect each item for possible shipping

damage. If damage is evident, contact

your distributor and / or shipping com-

pany before proceeding with the installa-

tion.

3. Record Power Supply and Torch model

and serial numbers, purchase date and

vendor name, in the information block at

the front of this manual.

3.02 Lifting Options

The Power Supply includes a handle for hand

lifting only. Be sure unit is lifted and transport-

ed safely and securely.

!

WARNING

Do not touch live electrical parts.
Disconnect input power cord before moving

unit.
FALLING EQUIPMENT can cause serious per-

sonal injury and can damage equipment.
HANDLE is not for mechanical lifting.

• Only persons of adequate physical strength

should lift the unit.

• Lift unit by the handles, using two hands.

Do not use straps for lifting.

• Use optional cart or similar device of ad-

equate capacity to move unit.

• Place unit on a proper skid and secure in

place before transporting with a fork lift or

other vehicle.

3.03 Primary Input Power

Connections

CAUTION

Check your power source for correct voltage

before plugging in or connecting the unit. The

primary power source, fuse, and any extension

cords used must conform to local electrical

code and the recommended circuit protection

and wiring requirements as specified in Sec-

tion 2.

All units are shipped from the factory with a

380/400Volt input power cable wired to the in-

put contactor in the three - phase configuration.

The following illustration and directions are for

replacing the input power cable.

Art # A-07983_AB

Three-Phase (3ø) and Jumper Settings

L1

L2

L3
L4

Jumper L1 -L4

L1
L2
L3

GND

L4

Store copper jumper in spare parts box

Three Phase Input Power Wiring

Advertising