04 fault indicator, Fault indicator -3 – Tweco CutMaster 12mm-20mm-25mm User Manual
Page 53
CUTMASTER 12mm, 20mm, 25mm
Manual 0-5117 5-3 SERVICE
5.04 Fault Indicator
At initial power up, two lights will temporarily illu-
minate for 2-3 seconds to show the version of software
used.
To determine the first digit, count the function indica-
tors left to right, 1 through 5. To determine the second
digit count the pressure indicators, reading from bot-
tom to top, 0 through 7. In the example below the Temp
indicator and 75 psi indicators are ON indicating the
version would be 2.3.
A
+
PSI
BAR
MAX
MAX
MIN
MIN
!
1 2 3 4
Art# A-07988
MIN
MAX
0
1
2
3
4
5
6
7
5
When the
!
"Fault" indicator is ON or blinking
it will be accompanied by one of the pressure in-
dicator lights depending on what the Fault is. The
following table explains each of those Faults.
Pressure
Indicator
Fault
Max
Over Pressure
90
Internal Error
85
Shorted Torch
80
Consumables Missing
75
Start Error
70
Parts in Place
65
Input Power
Min
Under Pressure
NOTE
Fault explanations are covered in the following
tables.