5.04 Fault Indicator

At initial power up, two lights will temporarily illu-

minate for 2-3 seconds to show the version of software

used.

To determine the first digit, count the function indica-

tors left to right, 1 through 5. To determine the second

digit count the pressure indicators, reading from bot-

tom to top, 0 through 7. In the example below the Temp

indicator and 75 psi indicators are ON indicating the

version would be 2.3.

A

+

PSI

BAR

MAX

MAX

MIN

MIN

!

1 2 3 4

Art# A-07988

MIN

MAX

0

1

2

3

4

5

6

7

5

When the

!

"Fault" indicator is ON or blinking

it will be accompanied by one of the pressure in-

dicator lights depending on what the Fault is. The

following table explains each of those Faults.

Pressure

Indicator

Fault

Max

Over Pressure

90

Internal Error

85

Shorted Torch

80

Consumables Missing

75

Start Error

70

Parts in Place

65

Input Power

Min

Under Pressure

NOTE

Fault explanations are covered in the following

tables.