Tweco CutMaster 12mm-20mm-25mm User Manual

Page 60

Advertising
background image

CUTMASTER 12mm, 20mm, 25mm

SERVICE 5T-2 Manual 0-5117

5T.02 Inspection and Replacement

of Consumable Torch Parts

WARNING

Disconnect primary power to the system be-

fore disassembling the torch or torch leads.
DO NOT touch any internal torch parts while

the AC indicator light of the Power Supply

is ON.

Remove the consumable torch parts as follows:

NOTE

The shield cup holds the tip and starter

cartridge in place. Position the torch with

the shield cup facing upward to prevent

these parts from falling out when the cup

is removed.

1. Unscrew and remove the shield cup from the

torch.

NOTE

Slag built up on the shield cup that cannot

be removed may effect the performance of

the system.

2. Inspect the cup for damage. Wipe it clean or

replace if damaged.

Art # A-08067

Shield Cups

3. On torches with a shield cup body and a shield

cap or deflector, ensure that the cap or deflector

is threaded snugly against the shield cup body.

In shielded drag cutting operations (only), there

may be an O-ring between the shield cup body

and drag shield cap. Do not lubricate the O-

ring.

Drag Shield Cap

Shield

Cup Body

O-Ring No. 8-3488

Art # A-03878

4. Remove the tip. Check for excessive wear (in-

dicated by an elongated or oversized orifice).

Clean or replace the tip if necessary.

Good Tip

Worn Tip

A-03406

Example of Tip Wear

5. Remove the starter cartridge. Check for exces-

sive wear, plugged gas holes, or discoloration.

Check the lower end fitting for free motion.

Replace if necessary.

Art # A-08064_AC

Spring-Loaded

Lower End Fitting

Full Compression

Spring-Loaded

Lower End Fitting at Reset /

Full Extension

6. Pull the Electrode straight out of the Torch

Head. Check the face of the electrode for exces-

sive wear. Refer to the following figure.

Worn Electrode

New Electrode

Art # A-03284

Electrode Wear

7. Reinstall the Electrode by pushing it straight

into the torch head until it clicks.

8. Reinstall the desired starter cartridge and tip

into the torch head.

9. Hand tighten the shield cup until it is seated

on the torch head. If resistance is felt when

installing the cup, check the threads before

proceeding.

This completes the parts replacement procedures.

Advertising