Section 3 torch: installation, 3t.01 torch connections, 3t.02 setting up mechanical torch – Tweco CutMaster 12mm-20mm-25mm User Manual

Page 27: Section 3 torch: installation t-1

Advertising
background image

CUTMASTER 12mm, 20mm, 25mm

Manual 0-5117 3T-1 INSTALLATION

SECTION 3 TORCH:

INSTALLATION

3T.01 Torch Connections

If necessary, connect the torch to the Power Sup-

ply. Connect only the Thermal Dynamics model

SL60 / Manual or SL100 / Mechanical Torch to

this power supply. Maximum torch leads length

is 100 feet / 30.5 m, including extensions.

WARNING

Disconnect primary power at the source before

connecting the torch.

1. Align the ATC male connector (on the torch

lead) with the female receptacle. Push the

male connector into the female receptacle.

The connectors should push together with

a small amount of pressure.

2. Secure the connection by turning the lock-

ing nut clockwise until it clicks. DO NOT

use the locking nut to pull the connection

together. Do not use tools to secure the

connection.

1

2

Art # A-07885

Connecting the Torch to the Power Supply

3. The system is ready for operation.

Check Air Quality

To test the quality of air:

1. Put the

ON / OFF

switch in the ON

(up) position.

2. Put the Function Control switch in the SET

position.

3. Place a welding filter lens in front of the

torch and turn ON the air. Do not start an

arc!

Any oil or moisture in the air will be visible

on the lens.

3T.02 Setting Up Mechanical Torch

NOTE

An adapter is required to be installed in the

power supply if converting a hand torch sys-

tem to operate a machine torch.

WARNING

Disconnect primary power at the source before

disassembling the torch or torch leads.

The mechanical torch includes a positioning

tube with rack and pinch block assembly.

1. Mount the torch assembly on the cutting

table.

2. To obtain a clean vertical cut, use a square

to align the torch perpendicular to the sur-

face of the workpiece.

Advertising