INSTALLATION

3-12

Manual 0-5100

CNC I/O Requirements for SC 3000 Electronic Enclosure

24 VDC

DISABLE

(9)

OK to MOVE (0 VDC or Contact)

24VDC COMM

(15)

OK to MOVE +

24 VDC

24 VDC

OK TO MOVE (20VDC or Contact)

OK to MOVE -

Plasma Start

Contact closure

or 20 VDC

(apply 24VDC)

(13)

PLASMA START (24 VDC)

24 VDC

(12)

(apply 24VDC)

24 VDC

(14)

J4 CNC

1

2

3

4

5

6

7

8

9

10

11

12

13

14

(10)

(11)

Height Control Disable 24VDC

24 VDC

24 VDC

(16)

OK

SW1

SW1

2

1

3

5

4

6

+20 VDC

Art # A-09091

Plasma Start and Height Control Disable require +24 VDC to activate. If the CNC outputs can supply

+24V it can be used directly if it is referenced to the 24 VDC Common at J4-2.

If the CNC has relays with NO contacts the 24 VDC available from the SC 3000 at J4-1, 3 & 10 may

be routed through those relays to supply the required input signal.

For other CNC outputs such as single ended open collector user supplied relays will need to be added.

Art # A-09092

CNC OUTPUT

'

+

USER RELAY

'

VDC

Use DCV from CNC for relay coil or if using 24 VDC from SC3000
must also connect CNC common to SC 3000 24 VDC COMM

'

'

'

'

'

'

'

'

24 VDC @ J4-1

24 VDC @ J4-3 or J4-10
START (J4-4 ) or DISABLE (J4-11)

DIODE

24 VDC COMM @ J4-2

Reverse EMF protection
Diode required for DC relay

Single ended.