Manual 0-5100

5-3

SERVICE

Fault Indication

Effect

Cause

Correction

Weight compensation

No initial position

finding

1.The hose of the torch pulls

upwards

1. Loosen the attachment of the hose

2.Setting of weight

compensation too strong

2. Turn knob at Linear Drive counter

clockwise.

Check of the weight compensation

described in chapter 4.

3. Switch of initial position

finding

3. Contact authorized service center for

repair or replacement

ARC Voltage

No finding of initial

position

Arc voltage is missed at

Interface

Check the connection between plasma

source and Interface..

Collision

Linear Drive moves

to upper reference

position

Collision protection was

active Torch moved against

a barrier

Eliminate the barrier.

Increase retract position if necessary.

Overload

No Movement

1. Load too much

1. Check the load

2. Motor Amplifier faulty

2. Contact authorized service center for

repair or replacement

3. Motor faulty

3. Contact authorized service center for

repair or replacement

Motor cables interchanged

After power on the

torch lifter moves

downwards instead of

upwards.

Motor cables interchanged Interchange motor connectors at pcb-board

Encoder

Torch lifter moves to

limit switch

Encoder or cable connection

faulty

Check the cables and connectors