Sc-3000, Cutting settings – Tweco SC-3000 User Manual

Page 46

Advertising
background image

SC-3000

OPERATION

4-6

Manual 0-5100

CUTTING SETTINGS

For detailed explanation go to section 4.12.

Mode Select

Device Info

ESC

Parameter Cutheight

Dependent on choice of

control mode

Pierce Delay

Dynamic

Elevation Height

Retract Position

Pierce Height

Control Delay

Upper Threshold

Gas Pre-Flow

System Properties

OK

Main Menu

Cutting Height

Select mm / inch

End of Cut

Operator Terminal

Display

Cutting Height

Ideal Voltage

Real Voltage

Time during piercing

Starts with signal START XY

Additional lifting during ignition

Distance during igntion

Reaction rate of clearance control

Blocking of clearance control when crossing kerfs

Height after end of cutting

Gas Pre-Flow starts with START INITIAL POSITION FINDING

Setting in percent of ideal arc voltage to detect end of cut

standard setting 85%

Height during cutting

Art # A-08930