Appendix 4: interface, Sc-3000 – Tweco SC-3000 User Manual

Page 75

Advertising
background image

SC-3000

Manual 0-5100

A-5

APPENDIX

APPENDIX 4: INTERFACE

The Interface is the central signal distribution point for the SC-3000™ System.

Art # A-08945

Features

• Power supply 24 VDC / 0.5A
• Connector to LINEAR DRIVE
• Connector to OPERATOR TERMINAL
• Interface for CUTBUS® used for serial communication to CNC
• Discrete Input / Output terminals 24 VDC to connect SC-3000™ to CNC-machine control system 2x17-remov-

able screw terminal strips. Special coding avoid mix-up.

• Integrated isolation amplifier for ARC voltage 0-10 VDC und 0-300 VDC from the plasma source
• 3 rotating switches to set
- Device address of Cutbus
- Baud rate for Cutbus
- optional range for ARC voltage
• LED’s for Ready, Communication and Fault
• Assembly on top hat rail for installation in a control cabinet

Technical Specifications

Input Voltage 24 VDC ±10%, with integrated reverse voltage protection

Input Plasma-ARC Voltage

Switch

setting

Input Voltage

range

Represents ARC

Voltage

Input resistance

0

0 to -300 VDC

0-300 VDC

ca. 3 MOhm

1

0 to +10 VDC

0-300 VDC

ca. 100 KOhm

2

0 to +6 VDC

0-300 VDC

ca. 100 KOhm

3

0 to +10V

0-250VDC

ca. 100 KOhm

Digital input of control signals

24 VDC ±10% / Resistor Ri

≈ 7 kOhm

Digital output of control signals

20 VDC / Resistor Ri

≈ 150 Ohm / short circuit proof

Advertising