Sc-3000 – Tweco SC-3000 User Manual
Page 76

SC-3000
APPENDIX
A-6
Manual 0-5100
Relay contact for “Enable Ignition”
Load 0.5A at 125VAC / 1A at 24 VDC
Baud rate
switch setting 0-4: 9600, 14400, 19200 28800, 38400
Address setting
0 - 3
Screw-on terminals
for wires max. 12 AWG (2.5 qmm)
Dimensions
3.5"x2.9"x4.4" (90x75x112 mm) Length x Width x Height
Mounting of Housing
on symmetric mounting rail according to EN 60715
Protection class
Housing IP40 / Clamps IP 20 according to
EN60529/IEC529
Environment conditions
no condensation at 32°-122°F (0-50°C) / 20-90% relative
humidity
Weight
0.73lbs. (0.33kg)
TDC part no.
9-0405
Digital input of control signals
R3
10k
R4 22k
R3
3,3k
C1
220n
R5 10k
74HCT14
GND
Input
Art # A-08946
Digital output of control signals
R1
10k
PTC
+24V
T1
125 Ohm
R2 22 Ohm
Output
D1
D2
GND
Art # A-08947