Sc-3000 – Tweco SC-3000 User Manual

Page 35

Advertising
background image

SC-3000

Manual 0-5100

3-13

INSTALLATION

OK to MOVE

OK to Move output from SC-3000 is factory set for relay contacts. SW1 on the PCB in the SC-3000

Electronic Enclosure can be set to supply 20-24 VDC through the OK to Move contacts. Total current

from all the 24 VDC should not exceed 500 ma. Too much current will blow F1, 1A fuse on the SC-

3000 Enclosure PCB.

Other Optional Functions

The SC-3000 Electronic Enclosure provides an access hole for user installed connections. Most of

these functions may be selected with the remote operators terminal but may be more convenient to have

separate controls for some of them.

Discrete signal

inputs X301

Discrete signal

ouputs X305

Art # A-09093

IHT 7250 Interface Module (inside Electronic Enclosure)