Installation/setup fabricator 252i – Tweco 252i Fabricator User Manual

Page 35

Advertising
background image

INSTALLATION/SETUP

FABRICATOR 252i

Manual 0-5155

3-5 INSTALLATION/SETUP

2. Fault Indicator

The yellow fault indicator will be illuminated when any

of the faults are detected. ALL Faults will illuminate the

indicator
3. Weld Process Selection Button

TIG

Process

MIG

STICK

Press and release this button to change the selected weld

process mode from MIG to LIFT TIG to STICK. The weld

process will change to the next process in the sequence

each time the button is pressed and released. The red

indicators next to the button will illuminate to identify MIG

or LIFT TIG or STICK process mode.

WARNING

When the Power light is lit, the machine is

connected to the Mains supply voltage and

the internal electrical components are at Mains

voltage potential.

4. 2T - 4T Trigger Latch Button

Trigger

2T Normal
4T Latch

Press and release the button to change the selected op-

erating mode of the trigger. The selected mode can be

either “2T” (unlatched) or “4T” (latched) operation. The

red indicator next to the button will illuminate to identify

which mode is selected (2T or 4T). In the 4T mode once

the weld has been started you can release the trigger and

continue welding until the trigger is activated again or the

welding arc is broken to stop the welding arc.

5. Advanced Features Button

Advanced

Features

Press and release the Advanced Features button to enter

or exit from the advanced programming mode. To exit,

simply press and release the button again. Any changes

made are saved. The advanced programming menu items

are described in detail for each welding mode in Section

3.07.

Advanced

Features

Gas Purge.

In addition, the Advanced Features Button is used to initi-

ate a 30 second gas line purge function to fill the gas line

with the shielding gas from the connected gas cylinder.

To start the gas purge function, simply press and hold the

button for approximately two (2) seconds. Once the Gas

purge function has started, a countdown timer will show

in the left alpha-numeric display indicating the number

of seconds remaining before the purge will be automati-

cally terminated. You can stop the Gas purge any time

during the 30 seconds by quickly pressing and releasing

the button again.