Fabricator 252i problems/service – Tweco 252i Fabricator User Manual

Page 84

Advertising
background image

FABRICATOR 252i

PROBLEMS/SERVICE

PROBLEMS AND ROUTINE SERVICE

5-4

Manual 0-5155

C. Earthing/Grounding

The resistance shall not exceed 1Ω between any metal of a power source where such metal is required to be

earthed, and -

1. The earth terminal of a fixed power source; or
2. The earth terminal of the associated plug of a transportable power source

Note that due to the dangers of stray output currents damaging fixed wiring, the integrity of fixed wiring sup-

plying Tweco welding power sources should be inspected by a licensed electrical worker in accordance with

the requirements below -

1. For outlets/wiring and associated accessories supplying transportable equipment - at least once every

3 months; and

2. For outlets/wiring and associated accessories supplying fixed equipment - at least once every 12 months.

D. General Maintenance Checks

Welding equipment should be regularly checked by an accredited Tweco Service Provider to ensure that:

1. Flexible cord is of the multi-core tough rubber or plastic sheathed type of adequate rating, correctly

connected and in good condition.

2. Welding terminals are in suitable condition and are shrouded to prevent inadvertent contact or short

circuit.

3. The Welding System is clean internally, especially from metal filing, slag, and loose material.

E. Accessories

Accessory equipment, including output leads, electrode holders, torches, wire feeders and the like shall be

inspected at least monthly by a competent person to ensure that the equipment is in a safe and serviceable

condition. All unsafe accessories shall not be used.

F. Repairs

If any parts are damaged for any reason, it is recommended that replacement be performed by an accredited

Tweco Service Provider.

Power Source Calibration

A. Schedule

Output testing of all Tweco Power Sources and applicable accessories shall be conducted at regular intervals

to ensure they fall within specified levels. Calibration intervals shall be as outlined below -

1. For transportable equipment, at least once every 3 months; and
2. For fixed equipment, at least once every 12 months.