Power source problems -1, Problems/service fabricator 252i, 01 power source problems – Tweco 252i Fabricator User Manual

Page 81

Advertising
background image

PROBLEMS/SERVICE

FABRICATOR 252i

Manual 0-5155

5-1

PROBLEMS AND ROUTINE SERVICE

SECTION 5: POWER SOURCE PROBLEMS AND ROUTINE SERVICE

REQUIREMENTS

5.01 Power Source Problems

Error Code

CAUSE

REMEDY

ERR

01

Over Temperature

Fault

OverTemp signal from

Power board indicates Over

temperature fault condition of

power components

A. Decrease duty cycle of welding activity

B. Ensure that air vents are not blocked/

obstructed

C. Consult an Accredited Tweco Service

Provider.

ERR

02

Input Power Fault

Signal from Power board

indicates input power voltage

is out of range (too high or

too low)

A. Check input power connections and cables

for damage or improper insertion

B. Verify input voltage levels meet product

requirements

ERR

03

VBIAS Voltage Low

Fault

Controller board circuit

monitor indicates 15 volt

supply is too low

(< 13.7 VDC)

Consult an Accredited Tweco Service Provider.

ERR

04

Ground Fault

Excessive current detected

on Ground wire of power

connection

A. Isolate welder chassis from work piece.

Check workpiece ground connection.

B. Check for MIG wire feed problem in spool/

feedplate. Verify wire is not contacting

chassis.

ERR

08

Input Sensor Fault

Unexpected reading of voltage

or current sensor during

power-up self test

A. Inspect ribbon cable between power supply

and display board.

B. Consult an accredited Tweco service

provider.

ERR

09

Fan Fault

Cooling Fan Failure detected

on Inverter board

A. Examine fan vents for potential obstruction.

B. Consult an Accredited Tweco Service

Provider.

ERR

10

Inverter Output Fault Substandard output voltage

condition detected by

controller before weld started

Consult an Accredited Tweco Service Provider.

ERR

14

Trigger Fault

Fault occurred detecting

trigger state/condition

A. Trigger may be already activated when MIG

process mode is selected - verify that trigger

is not accidentally activated

B. Trigger may be faulty and/or dirty, test and

replace MIG Gun/trigger device

ERR

15

Wirefeed Fault

Welder detects prolonged

open circuit during MIG weld

A. Inspect MIG wire spool and feedplate for

improper tension or 'bird's nest'.

B. Inspect MIG Gun and cable for damage or

obstruction

C. Consult an Accredited Tweco Service

Provider.

ERR

23

Weld Fault

Welder detected a fault during

the weld process

Consult an Accredited Tweco Service Provider

if symptom recurs frequently.