INSTALLATION/SETUP

FABRICATOR 252i

Manual 0-5155

3-15 INSTALLATION/SETUP

Function

Left Display

Right Display

(Factory De-

fault Values)

Limits

Comments

Hot Start

HOT/STRT

ON

OFF – ON

Hot Start is used to improve the start character-

istics for STICK electrodes, e.g. low hydrogen

electrodes.

Hot Start Time

TIME/HS

0.5 S

0.0 - 2.0 S

Hot Start Time is the time that the Hot Start

Amps is applied.

Hot Start Amps

AMPS/HS

140%

75 – 200%

Hot Start Amps sets the peak start current, e.g.

100A at 140% = 140A

Arc Hour Accu-

mulated Run-

time

HR

0.0

0.0 – 9999.9

Provides Arc On Hours that the power source

has welded. The number displayed is in hours

and read only. It will rollover to 0 once 10,000

hours have been reached.

Restore Factory

Defaults

FACT/DFLT

NO

NO – YES

When YES is selected all the user adjustable val-

ues in this table (except Arc Hour Accumulated

Runtime) are reset to the Factory Default Values.

3.08 Attaching the Tweco Fusion 250A MIG Gun

1. Unscrew the Locking Screw in the MIG Gun Adapter located inside the Wire Feed Compartment.
2. Push the Tweco Fusion 250A MIG Gun into MIG Gun Adaptor firmly using a twisting action.
3. Lock the Tweco Fusion 250A MIG Gun into the MIG Gun Adaptor by turning the Locking Screw clockwise in

the MIG Gun Adapter within the Wire Feed Compartment to secure the Tweco Fusion 250A MIG Gun in posi-

tion.

NOTE

Failure to properly lock the Tweco Fusion 250A MIG Gun into the MIG Gun Adapter will result in the Tweco

Fusion 250A MIG Gun being pushed out of the MIG Gun Adapter by the MIG welding wire or lack of shield-

ing gas (porosity in the weld) at the weld zone.

+

-

Attach MIG Gun

and secure.

Art # A-10548

Remote Cable 8 pin connector

Figure 3-8: Mount Fusion MIG Gun Cable to Adapter Socket