Manual 0-5155

ERR

24

Code Memory Fault Welder detected a fault in

program flash memory

Firmware image is corrupted. Consult an

Accredited Tweco Service Provider.

ERR

25

Nonvolatile Memory

Fault

Welder detected a fault in

parameter NVROM.

A. Welding may still be possible, but no weld

setting changes can be saved.

B. Consult an Accredited Tweco Service

Provider.

ERR

26

Unknown PCB Fault Welder control board cannot

identify an attached inverter

board and/or determine its

own identity

Consult an Accredited Tweco Service Provider.

ERR

30

Service Mode Switch

Fault

SERVICE DIP switch is

enabled

Welding is disabled while SERVICE Mode DIP

switch is enabled. Disable SERVICE Mode

switch to resume welding.

ERR

31

Controller Fault

Welder control board has

detected a hardware fault on

itself

Consult an Accredited Tweco Service Provider

if symptom recurs frequently.

ERR

33

Calibration Fault

An output (current, voltage,

or motor) fault was detected

while attempting a calibration

process

A. Check integrity of welder cables, MIG Gun

or electrode holder and retry calibration.

B. Check MIG wire spool, feedplate area for

wire feed issues, correct and retry calibration

ERR

34

User Calibration

Abort

User-initiated abort/

interruption of an active

calibration process occurred

(usually, release of trigger too

early)

Restart/reselect calibration process and retry

calibration when ready.

ERR

35

Parameter Fault

Welder control board has

detected a parameter out of

range

System Parameter re-initialization has been

automatically performed or is required

(Factory Default Reset)

Note 1: If the left display is alternate flashing "Err" and "Code" this is indicating that the fault was detected

but has either stopped occurring or is in the process of clearing itself. If this is the case, the flashing error

message will return to normal display functionality within 10 seconds unless another fault occurs. If the left

display shows a steady "Err" this is indicating that the fault is persistent and is still being detected.
Note 2: Flashing Amperage and Voltage displays (when welding) indicates that the machines maximum

output power rating (300A x 26.7V = 8kVA) is being exceeded and the system is automatically reducing the

output. If welding is ceased while the displays are flashing, the last values will be displayed for 10 seconds or

until controls are adjusted.

Table 5-1: Power Source Problems