Set-up for lift tig (gtaw) welding -28, Fabricator 252i installation/setup – Tweco 252i Fabricator User Manual

Page 58

Advertising
background image

FABRICATOR 252i

INSTALLATION/SETUP

INSTALLATION/SETUP 3-28

Manual 0-5155

2. Check that the MIG wire size, contact tip, MIG Gun liner and drive roll groove are all the same size before fitting

the MIG wire into the Power Source.

3. Connect the MIG Gun Polarity Lead to the negative welding terminal (-). If in doubt, consult the MIG electrode

wire manufacturer. Welding current flows from the Power Source via heavy duty bayonet type terminals. It is

essential, however, that the male plug is inserted and turned securely to achieve a sound electrical connection.

4. Fit the MIG (FCAW) wire spool and MIG Gun to the Power Source. (Refer to section 3.08 to 3.12).
5. Connect the work lead to the positive welding terminal (+). If in doubt, consult the MIG electrode wire manu-

facturer. Welding current flows from the Power Source via heavy duty bayonet type terminals. It is essential,

however, that the male plug is inserted and turned securely to achieve a sound electrical connection.

6. If gasless MIG (FCAW) wire is fitted then shielding gas is not required for welding. Otherwise fit the welding

grade shielding gas regulator/flow gauge to the shielding gas cylinder (refer to Section 3.17) then connect the

shielding gas hose from the rear of the power source to the regulator/flow gauge outlet.

7. Turn the Main ON/OFF switch ON (located on the rear panel).
8. Select MIG mode with the process selection control. (Refer to Section 3.06.4 for further information)
9. Remove the MIG Gun nozzle and contact tip.
10. Depress MIG Gun trigger to feed the MIG wire out. Then fit the contact tip on the MIG wire and hand tighten

the nozzle in place.

11. Refer to the Weld Guide located on the inside of the wire feed compartment door for further information on

Voltage/Wirespeed settings.

WARNING

Before connecting the work clamp to the work make sure the mains power supply is switched OFF.

CAUTION

Loose welding terminal connections can cause overheating and result in the male plug being fused in the

terminal.
Remove any packaging material prior to use. DO NOT block the air vents at the front or rear of the Welding

Power Source.

NOTE

Depending on the type of wire you will be using the MIG Gun polarity may need to be switched. Follow the

wire manufacturers recommendation.

3.20 Set-up for LIFT TIG (GTAW) Welding

!

WARNING

Before any welding is to begin, be sure to wear all appropriate and recommended safety equipment.

NOTE

The following steps will assume that you have already set up the proper shielding gas as outlined in Sub

Section 3.17.