2.08 Duty Cycle

The rated duty cycle of a Welding Power Source, is a statement of the time it may be operated at its rated weld-

ing current output without exceeding the temperature limits of the insulation of the component parts. To explain

the 10 minute duty cycle period the following example is used. Suppose a Welding Power Source is designed to

operate at a 20% duty cycle, 200 amperes at 18.0 volts. This means that it has been designed and built to provide

the rated amperage (200A) for 2 minutes, i.e. arc welding time, out of every 10 minute period (20% of 10 minutes

is 2 minutes). During the other 8 minutes of the 10 minute period the Welding Power Source must idle and be

allowed to cool. The thermal cut out will operate if the duty cycle is exceeded.