08 installing minispool (100mm diameter), Installation/setup 186 ac/dc inverter – Tweco 186 DC Inverter User Manual

Page 41

Advertising
background image

Manual 0-5237

3-11

INSTALLATION, OPERATION AND SETUP

INSTALLATION/SETUP 186 AC/DC INVERTER

Programming Parameter

Adjustment Device

Display

Hot Start

This parameter operates in all weld modes

except LIFT TIG mode and is used to heat up

the weld zone in TIG modes or improve the

start characteristics for stick electrodes the

peak start current on top of the WELD current.

e.g. HOT START current = 130 amps when

WELD = 100 amps & HOT START = 30 amps

Amps

0 to 70A (max 170A weld current)

Weld Current

This parameter sets the TIG WELD current

when PULSE is OFF. This parameter also sets

the STICK weld current.

Amps

5 to 170A (DC STICK mode)

10 to 170A (AC STICK mode)

Arc Force (STICK Mode only)

Arc Force is effective when in STICK Mode

only. Arc Force control provides and adjustable

amount of Arc Force (or "dig") control. This

feature can be particularly beneficial in

providing the operator the ability to compensate

for variability in joint fit-up in certain situations

with particular electrodes. In general increasing

the Arc Force control toward 100% (maximum

Arc Force) allows greater penetration control to

be achieved.

V
SEC
%
Hz

Volts

0 to 100%

Table 3-3

3.10 186 AC/DC – LIFT TIG and HF TIG Programming Mode

Press the PROCESS SELECTION button to select LIFT TIG or HF TIG mode.
Press the MODE switch to toggle between AC and DC welding output.
Press FORWARD or BACK to cycle through available programming functions.
Use the Multi Function Control to adjust the parameter selected.