Installation/setup 186 ac/dc inverter – Tweco 186 DC Inverter User Manual

Page 45

Advertising
background image

Manual 0-5237

3-15

INSTALLATION, OPERATION AND SETUP

INSTALLATION/SETUP 186 AC/DC INVERTER

Programming Parameter

Adjustment Device

Display

Wave Balance

This parameter operates in AC

TIG mode and is used to set the

penetration to cleaning action

ratio for the AC weld current.

Generally WAVE BALANCE is set

to 50% from the factory for AC

TIG Welding. The WAVE BALANCE

control changes the ratio of

penetration to cleaning action of

the AC TIG welding arc. Maximum

weld penetration is achieved

when the WAVE BALANCE control

is set to 10%. Maximum cleaning

of heavily oxidized aluminium or

magnesium alloys is achieved

when the WAVE BALANCE control

is set to 65%.

V
SEC
%
Hz

Volts

10 to 65%

Table 3-4

WAVE BALANCE is used for aluminium welding in AC HF TIG or AC LIFT TIG mode
It is used to set the ratio of penetration to cleaning action for the AC TIG welding arc.
Maximum weld penetration is achieved when the WAVE BALANCE is set to 10%. Maximum cleaning of heavily

oxidized aluminium or magnesium alloys is achieved when the WAVE BALANCE is set to 65%.

Maximum Penetration and

reduced cleaning

Balanced with 50% penetration

and 50% cleaning

Maximum Cleaning and

reduced penetration

10%

50%

65%

90%

50%

35%

(+)

(+)

(+)

(-)

(-)

(-)

Wave Balance = 50%

Wave Balance = 10%

Wave Balance = 65%

A-11223

Table 3-5: AC TIG Wave Balance

Advertising