Installation/setup 186 ac/dc inverter – Tweco 186 DC Inverter User Manual

Page 43

Advertising
background image

Manual 0-5237

3-13

INSTALLATION, OPERATION AND SETUP

INSTALLATION/SETUP 186 AC/DC INVERTER

Programming Parameter

Adjustment Device

Display

Up Slope

This parameter operates in (4T)

TIG modes only and is used to

set the time for the weld current

to ramp up, after the torch trigger

switch has been pressed then

released, from Initial Current to

High or Weld current.

V
SEC
%
Hz

Volts

0.0 to 15.0 seconds

Weld Current

This parameter sets the TIG

WELD current when PULSE is

OFF. This parameter also sets the

STICK weld current.

Amps

5 to 200A (DC TIG mode)

30 to 200A (AC LIFT TIG mode)

10 to 200A (AC HF TIG mode)

High Current

This parameter sets the High weld

current when in PULSE mode.

Amps

10 to 200A (DC TIG mode)

30 to 200A (AC TIG mode)

Low Current

The lowest point in the pulse is

called the Low Current.

Amps

5 to 200A (DC HF TIG mode)

30 to 200A (AC LIFT TIG mode)

10 to 200A (AC HF TIG mode)

Pulse Width

This parameter sets the

percentage on time of the PULSE

FREQUENCY for High weld

current when the PULSE is ON.

V
SEC
%
Hz

Volts

15 to 80%

Pulse Frequency

This parameter sets the PULSE

FREQUENCY when the PULSE is

ON.

V
SEC
%
Hz

Volts

0.5 to 200 Hz

Advertising
This manual is related to the following products: