2.09 Specifications

Description

Thermal Arc 186 AC/DC INVERTER

Part Number

W1006300

Power Source Weight

48.4lbs (22 kg)

Power Source Dimensions

H15.75"xW9.45"xD18.7"

(H 400mm x W 240mm x D 475mm)

Cooling

Fan Cooled (Runs Continually)

Welder Type

Inverter Power Source

Applicable Standards / Approvals

CSA E60974-1-00 / UL60974-1 / IEC 60974-1

Number of Phases

1

Nominal Supply Frequency

50/60Hz

Welding Current Range (STICK Mode)

5 - 170A (DC Stick)

10-170A (AC Stick)

Welding Current Range (TIG Mode)

5 - 200A (DC TIG)

30-200A (AC LIFT TIG)

10-200A (AC HF TIG)

Nominal Supply Voltage

208V

230V

Effective Input Current (I

1eff

) (See Note 1)

STICK
TIG

16.4A
16.5A

15.5A
14.1A

Maximum Input Current (I

1max

)

STICK
TIG

35.6A
35.4A

34.9A
32.4A

Single Phase Generator Requirement (See Note 2)

9.5KVA (7KW)

STICK (SMAW)
Welding Output, 40ºC, 10 min.

170A @ 15%, 26.8V
100A @ 60%, 24.0V
80A @ 100%, 23.2V

TIG (GTAW)
Welding Output, 40ºC, 10 min.

200A @ 20%, 18V

116A @ 60%, 14.6V
90A @ 100%, 13.6V

Open circuit voltage

70.3 VDC / 50VAC

Protection Class

IP23S

Table 2-1: 186 AC/DC Specification

Note 1: The Effective Input Current should be used for the determination of cable size & supply requirements.