INSTALLATION, OPERATION AND SETUP

3-22

Manual 0-5237

186 AC/DC INVERTER INSTALLATION/SETUP

NOTE

When the 186 AC/DC is used with a Remote Foot Control in, depress foot control to maximum to allow

max current to be previewed/adjusted on the front panel. To avoid premature arcing, please ensure the

TIG Torch is located away from your work piece.

3.15 Setup for STICK (SMAW) Welding

A. Connect the Electrode Holder lead to the positive welding terminal (+). If in doubt, consult the electrode

manufacturer. Welding current flows from the Power Source via heavy duty bayonet type terminals. It is

essential, however, that the male plug is inserted and turned securely to achieve a sound electrical connection.

B. Connect the work lead to the negative welding terminal (-). If in doubt, consult the electrode manufacturer.

Welding current flows from the power source via heavy duty bayonet type terminals. It is essential, however,

that the male plug is inserted and turned securely to achieve a sound electrical connection.

C. Select STICK mode with the process selection control (refer to Section 3.08.7 for further information)

!

WARNING

Before connecting the work clamp to the work and inserting the electrode in the electrode holder

make sure the mains power supply is switched off.

CAUTION

Remove any packaging material prior to use. Do not block the air vents at the front or rear of the

Welding Power Source.

CAUTION

Loose welding terminal connections can cause overheating and result in the male plug being fused in

the bayonet terminal.