186 AC/DC INVERTER SERVICE

POWER SOURCE PROBLEMS AND ROUTINE SERVICE REQUIREMENTS 5-2 Manual 0-5237

FAULT

CAUSE

REMEDY

Error Code “Err 001” is

displayed on the digital

displays in conjunction

with the Fault Indicator

Illuminating.

A Thermal Overload

This is due to the duty cycle of

the power source being exceeded.

Once the power source cools

sufficiently it will automatically

reset and the Fault Indicator and

Err 001 will go off and the power

source is then able to continue

welding. During the time of

cooling the power source should

remain ON such that the fan

continues to operate allowing the

unit to cool sufficiently. If after 30

minutes with the fan running the

Fault Indicator has not gone OFF

then have an Accredited Thermal

Arc Service Provider check the

power source.

B Primary Circuit Overload

This is due to primary circuit

component(s) malfunctioning

which results in excessive primary

circuit current. Switch the power

source to OFF immediately to

allow all components to cool

down for at least 30 minutes.

If after 30 minutes “Err 001” is

displayed and Fault Indicator

illuminates when the power

source is switched back ON turn

the power source OFF and have an

Accredited Thermal Arc Service

Provider check the power source.

Table 5-1: Power Source Problem

5.03 Routine Service and Calibration Requirements

!

WARNING

There are extremely dangerous voltage and power levels present inside this Inverter Power Source. Do

not attempt to open or repair unless you are an accredited Thermal Arc Service Provider. Disconnect

the Welding Power Source from the Mains Supply Voltage before disassembling.

Routine Inspection, Testing & Maintenance
The inspection and testing of the power source and associated accessories shall be carried out in accordance

with Section 5 of EN 60974.1: Safety in Welding and Allied Processes-Part 2 Electrical. This includes an insula-

tion resistance test and an earthing test to ensure the integrity of the unit is compliant with Thermal Arc original

specifications.
If equipment is to be used in a hazardous location or environments with a high risk of electrocution as outlined in

EN 60974.1, then the above tests should be carried out prior to entering this location.