186 ac/dc inverter installation/setup – Tweco 186 DC Inverter User Manual

Page 42

Advertising
background image

INSTALLATION, OPERATION AND SETUP

3-12

Manual 0-5237

186 AC/DC INVERTER INSTALLATION/SETUP

I

z

I

s

I

2

I

e

I

1

MODE

PULSE

PURGE

PROCESS

LIFT TIG

V
SEC
%
Hz

HF TIG

STICK

2T

4T

TRIGGER

BACK

FORWARD

AC FREQUENCY

P O R T A B L E W E L D I N G S Y S T E M

WAVE BALANCE
ARC FORCE

Pre

Flow

Post

Flow

Initial

Current

Up

Slope

Down

Slope

Crater

Current

Weld

Current

Frequency

f

w

Width

High Current

Low

Current

Hot

Start

t1

t2

A

V

Press to go forward / go back

between programming status

LED’s

Adjust programming parameter

using the Multi Function Control knob

A-11497_AB

Figure 3-6: LIFT TIG and HF TIG Programming Mode

Programming Parameter

Adjustment Device

Display

Pre-Flow

This parameter operates in

TIG modes only and is used to

provide gas to the weld zone

prior to striking the arc, once

the torch trigger switch has been

pressed. This control is used to

dramatically reduce weld porosity

at the start of a weld.

V
SEC
%
Hz

Volts

0.0 to 1.0 second

Initial Current

This parameter operates in (4T)

TIG modes only and is used to

set the start current for TIG. The

Start Current remains on until the

torch trigger switch is released

after it has been depressed.

Note: The maximum initial current

available will be limited to the set

value of the weld current.

Amps

5 to 200 Amps (DC TIG mode)

30 to 200 Amps (AC LIFT TIG mode)

10 to 200A (AC HF TIG mode)

Advertising