Tweco 9-8587 User Manual
Page 3
Advertising
Manual 0-5185
3
Figure 4: Air Hose, Transformer and Worklead Connections
4. Remove the T-20 Torx screws from the contactor base both front and rear.
Figure 5: Front Contactor Mounting Screw Figure 6: Rear Contactor Mounting Screw
5. (SKIP this step if unit contains an CE Filter)To assist with the contactor removal, it is recommended to loosen/
remove the AC power cord grip from the rear of the Cutmaster. This will allow the cord to be pushed/pulled
through the Cutmaster rear panel.
Figure 7: Cord Grip Removal