9. Pull the contactor away from the PCB and expose the harness wires attached to the LINE side of the contactor in

the previous step. Move the previously detached ‘A’ and ‘B’ black sleeved wires from in front of, to behind the

contactor wires #1, #2, #5 & #6. Re-attach the ‘A’ and ‘B’ wires to the Main PCB. Keep wires twisted as original

and run over the top of the enclosure. Figure 15. Cut the wire tie on the contactor harness, Figure 16. Rotation

of the CE Filter ground wire may be necessary for fit of the contactor box. Figure 17.

Figure 14: Transformer Wires Before Relocation Figure 15: Transformer Wires After Relocation

Figure 16: Cut Wire Tie Figure 17: Rotate CE Filter Wire