Re-Assembly
13. Re-attach the worklead ‘Work1’ connection and torque to 17 +/-1 in/lbs. Connect the internal gas filter hose
previously removed. Orient transformer and Contactor wires so that they are not pinched or pressed up against
the PCB and the installed enclosure top. Also see Figure 15.
Figure 23: Worklead Connection re-installed Figure 24: Hose re-installed
Figure 25: Installation for Cutmaster 40mm
14. Re-install the Metal Cover and secure with the previously removed screws. Install to 17+/-1 in/lbs. Re-tighten
cord grip on AC power cord to 34+/-1 in/lbs. Cord should not pull from the unit.