4

Contactor Replacement

6. Remove the contactor from the metal base of the Cutmaster.

CAUTION

NOTE ALL WIRE LOCATIONS. DO NOT MISWIRE UNIT AS NON-REPAIRABLE DAMAGE WILL

OCCUR TO THE CONTACTOR AND PCB.

NOTE

Notations in following illustration designate permanent wire connections to the 9X160 contactor. Addi-

tional connections are noted for single and three phase on the labels internal to the True Series CutMaster

and next to the contactor (if applicable).

7. Reconnect AC power cord as previous. USE T-20 Torx Screwdriver on contactor connection lugs, use needle

nosed pliers on spade connections. CM 12, 20, 25 & 40 UNITS WITH CE FILTERS: Remove wires #5 & #6 from

the contactor and replace with the harness included with the enclosure kit. This will involve clipping wire ties

as in Figure 16. Remove J6 from the Main PCB and replace with the harness connection.

Figure 8: Load Side Connections Figure 9: Line Side Connections

NOTE

An additional #10AWG black wire jumper may be connecting L1 to L4, re-install this, if present and bend

wire to fit the enclosure. See Figure 20.