Viking Pump TSM280: Duralobe (Discontinued) User Manual

Page 50

Advertising
background image

Page : 48

- Gently push the stationary seat and o-ring assemblies (30 and 31) into the

thrust rings (42), ensuring drive pins and slots are engaged.

- You should now be able to feel the resistance being generated by the

wave springs (29).


- Before final assembly, check that the seal faces are absolutely clean, use

a soft tissue and a suitable solvent based cleaner for best results.


Disassembly of Single Flushed Mechanical Seals.

Ensure pump is fully shutdown, refer to section 3.5.

To disassemble, reverse the above procedure using the extraction tool
supplied to aid in the removal of the seal faces, see fig 27.

-

Remove rotary seal faces (33) from the rotors (41 see fig 5.6) using the
extraction tool (61). This is achieved by inserting the extraction tool
between the rotary seal face (33) and the rotor (41) and applying a
twisting action, see fig 27. It may be necessary to alternate from side to
side to facilitate removal.


-

The static seal face (31) can be removed by using the same technique.


Note: Extreme care should be taken when carrying out these procedures
to ensure that the seal faces are not damaged. No excessive force is
necessary if the extraction tool is used correctly.

WARNING