4.3.10 Hybrid Single Flushed Mechanical Seal

Fig 37






















- During Pump assembly fit the seal housing (28) to the rotorcase securing

with screws (26) tightening to correct torque, refer to section 5.2. Ensure
the gasket or o-ring (27) are in place before tightening screws (26)


- Install o-ring (49) into the seal carrier (44).

- Install lip seal (43) into the seal carrier (44) and secure using the retainer

clip (42).

- Install seal assembly (comprising parts 42, 43, 44, 49) into the rotorcase,

ensure anti-rotation lugs engage.


- Install o-ring (50) into the static seal seat (31).

- Install seal seat assembly (comprising parts 30, 31) to the rotorcase,

ensuring that the drive lugs and the drive slots engage.

- Install o-ring (32) into the rotary seal face (33).

- Install seal assembly (comprising parts 32, 33) into the rotor.

- To disassemble reverse the above procedure.

- Before disassembling the seals, ensure pump is fully shutdown, refer to

section 3.5.