4.3.15 MK2 Double O-ring Seal S2, S3, S4
Fig

42


























- During Pump assembly fit the stop washers (160) to the rotorcase securing

with screws (26) tightening to correct torque, refer to section 5.2.


- Install O-rings (154) onto the rotorcase sleeve (158).

- Install Sleeve assembly (comprising parts 154, 158) Into the

Rotorcase

(40).

Note:- that the sleeve is a press fit so ensure that the sleeve is square

when pressing it into the rotorcase and it is against the stop washers.


- Install O-ring (155) onto the Rotor (41).

- Install the rotor (41) onto the shaft making sure not to damage the o-ring

(155).


- To disassemble reverse the above procedure.

- Before disassembling the seals, ensure pump is fully shutdown, refer to

section 3.5.